标题:Total variation superiorization schemes in proton computed tomography image reconstruction

作者:S. N. Penfold, R. W. Schulte, Y. Censor, A. B. Rosenfeld
查看论文《Total variation superiorization schemes in proton computed tomography image reconstruction》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: Iterative projection reconstruction algorithms are currently the preferred reconstruction method in proton computed tomography (pCT). However, due to inconsistencies in the measured data arising from proton energy straggling and multiple Coulomb scattering, noise in the reconstructed image increases with successive iterations. In the current work, we investigated the use of total variation superiorization (TVS) schemes that can be applied as an algorithmic add-on to perturbation-resilient iterative projection algorithms for pCT image reconstruction. Methods: The block-iterative diagonally relaxed orthogonal projections (DROP) algorithm was used for reconstructing Geant4 Monte Carlo simulated pCT data sets. Two TVS schemes added on to DROP were investigated; the first carried out the superiorization steps once per cycle and the second once per block. Simplifications of these schemes, involving the elimination of the computationally expensive feasibility proximity checking step of the TVS framework, were also investigated. The modulation transfer function and contrast discrimination function were used to quantify spatial and density resolution, respectively. Results: With both TVS schemes, superior spatial and density resolution was achieved compared to the standard DROP algorithm. Eliminating the feasibility proximity check improved the image quality, in particular image noise, in the once-per-block superiorization, while also halving image reconstruction time. Overall, the greatest image quality was observed when carrying out the superiorization once-per-block and eliminating the feasibility proximity check. Conclusions: The low contrast imaging made possible with TVS holds a promise for its incorporation into our future pCT studies.
评论: 26pp, Medical Physics, accepted for publication
主题: 医学物理 (physics.med-ph); 优化与控制 (math.OC)
引用方式: arXiv:1010.1663 [physics.med-ph]
  (或者 arXiv:1010.1663v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1010.1663
期刊参考: Medical Physics, Vol. 37, pp. 5887-5895, (2010)
相关 DOI: https://doi.org/10.1118/1.3504603

提交历史

来自:Yair Censor
[v1] 2015年5月20日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

math.OC
< 上一篇   |   下一篇 >
最新 | 近期 | 2015-05
切换浏览方式为:
physics
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站