标题:Coil Creep and Skew-Quadrupole Field Components in the Tevatron
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:During the first 20 years of operation, the Fermilab Tevatron developed strong coupling between the two transverse degrees of freedom. The required strength of the circuit of skew quadrupole magnets used to correct for coupling, though capable, had increased by an order of magnitude since 1983. Changes made to the Tevatron for colliding beams operation had altered the skew quadrupole corrector distribution and strong coupling became evident, often encumbering routine operation during the colliding beam physics run. It was discovered that the superconducting coils of the main dipole magnets had become vertically displaced relative to their yokes since their construction. The ensuing systematic skew quadrupole field introduced by this displacement accounts for the required corrector settings and observed beam behavior. The magnets were adjusted in situ over the course of several long maintenance periods and the Tevatron performance improved as a result.
提交历史
来自:Harding, David J.[v1] 2012年9月25日 星期二 16:00:35 UTC