标题:Output and $k_{Q_{clin},Q_{msr}}^{f_{clin},f_{msr}}$ correction factors measured and calculated in very small circular fields for microDiamond and EFD-3G detectors

作者:Eyad Alhakeem, Sergei Zavgorodni
查看论文《Output and $k_{Q_{clin},Q_{msr}}^{f_{clin},f_{msr}}$ correction factors measured and calculated in very small circular fields for microDiamond and EFD-3G detectors》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The purpose of this work was to obtain output correction factors for microDiamond and EFD-3G detectors in very small (less than 5 mm) circular fields. We also investigated the impact of possible variations in microDiamond detector design schematics on the calculated correction factors. Output factors (OFs) of 6MV beams from TrueBeam linac collimated with 1.27-40mm diameter cones were measured with EBT3 films, microDiamond and EFD-3G detectors as well as calculated (in water) using Monte Carlo (MC) methods. Based on EBT3 measurements and MC calculations output correction factors were derived for these detectors. MC calculations were performed for microDiamond detector in parallel and perpendicular orientations relative to the beam axis. Furthermore, correction factors were calculated for two microDiamond detector models, differing by the presence or absence of metallic pins. The measured OFs agreed within 2.4% for fields $\geqslant$10mm. For the cones of 1.27, 2.46, and 3.77mm maximum differences were 17.9, 1.8 and 9.0%, respectively. MC calculated output factors in water agreed with those obtained using EBT3 film within 2.2% for all fields. MC calculated output correction factors for microDiamond detector in fields $\geqslant$10mm ranged within 0.975-1.020 for perpendicular and parallel orientations. MicroDiamond detector correction factors calculated for the 1.27, 2.46 and 3.77mm fields were 1.974, 1.139 and 0.982 with detector in parallel orientation, and these factors were 1.150, 0.925 and 0.914 in perpendicular orientation. Including metallic pins in the microDiamond model had little effect on calculated correction factors. EBT3 and MC obtained correction factors agreed within 3.7% for fields of $\geqslant$3.77mm and within 5.9% for smaller cones. Including metallic pins into the detector model is not necessary as their presence/absence had no effect on calculated correction factors.
评论: 23 pages with 7 figures
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1802.00569 [physics.med-ph]
  (或者 arXiv:1802.00569v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1802.00569
相关 DOI: https://doi.org/10.1088/1361-6560/aacfb2

提交历史

来自:Eyad Alhakeem
[v1] 2018年8月15日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-08
切换浏览方式为:
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站