跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:2001.02424 (physics)
[提交于 2020年1月9日]

标题:Photon arrival time tagging with many channels, sub-nanosecond deadtime, very high throughput, and fiber optic remote synchronization

作者:Michael Wahl, Tino Roehlicke, Sebastian Kulisch, Sumeet Rohilla, Benedikt Kraeamer, Andreas C. Hocke
查看论文《Photon arrival time tagging with many channels, sub-nanosecond deadtime, very high throughput, and fiber optic remote synchronization》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Time-Correlated Single Photon Counting (TCSPC) and time tagging of individual photon detections are powerful tools in many quantum optical experiments and other areas of applied physics. Using TCSPC, e.g., for the purpose of fluorescence lifetime measurements, is often limited in speed due to dead-time losses and pile-up. We show that this limitation can be lifted by reducing the dead-time of the timing electronics to the absolute minimum imposed by the speed of the detector signals while maintaining high temporal resolution. A complementing approach to speedy data acquisition is parallelization by means of simultaneous readout of many detector channels. This puts high demands on the data throughput of the TCSPC system, especially in time tagging of individual photon arrivals. Here, we present a new design approach, supporting up to 16 input channels, an extremely short dead-time of 650 ps, very high time tagging throughput, and a timing resolution of 80 ps. In order to facilitate remote synchronization of multiple such instruments with highest precision, the new TCSPC electronics provide an interface for White Rabbit fiber optic networks. Beside fundamental research in the field of astronomy, such remote synchronization tasks arise routinely in quantum communication networks with node to node distances on the order of tens of kilometers. In addition to showing design features and benchmark results of new TCSPC electronics, we present application results from spectrally resolved and high-speed fluorescence lifetime imaging in medical research. We furthermore show how pulse-pile-up occurring in the detector signals at high photon flux can be corrected for and how this data acquisition scheme performs in terms of accuracy and efficiency.
评论: 34 pages, 9 figures, accepted by Review of Scientific Instruments
主题: 仪器与探测器 (physics.ins-det); 数据分析、统计与概率 (physics.data-an); 组织与器官 (q-bio.TO)
引用方式: arXiv:2001.02424 [physics.ins-det]
  (或者 arXiv:2001.02424v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.2001.02424
相关 DOI: https://doi.org/10.1063/1.5121412

提交历史

来自:Michael Wahl
[v1] 2020年1月9日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-01
切换浏览方式为:
physics.ins-det
physics.data-an
q-bio.TO

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站