物理学 > 医学物理

arXiv:2611.00519 (physics)
[提交于 2026年10月31日]

标题:Simulation analysis of a direct/indirect conversion dual-layer X-ray detector for early identification of coronary artery calcium

作者:Akyl Swaby, Linxi Shi, Kaitlin Hellier, Adam S. Wang, Shiva Abbaszadeh
查看论文《Simulation analysis of a direct/indirect conversion dual-layer X-ray detector for early identification of coronary artery calcium》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Coronary artery calcification (CAC) is a strong predictor of future cardiovascular events, and CAC burden is commonly used to stratify patient cardiovascular risk. Although CAC is typically quantified using computed tomography, routine chest radiography offers an opportunity for lower-dose, widely available opportunistic screening. Single-exposure dual-energy chest radiography using multilayer flat-panel detectors can generate low- and high-energy images without motion artifacts and provide material decomposition parameters, including calcification density. In this work, we investigate a direct/indirect dual-layer detector consisting of an amorphous selenium (a-Se) direct-conversion top layer and a cesium iodide scintillator-based indirect-conversion bottom layer for enhanced visualization of small CAC. A cascaded linear systems model (CLSM) simulated task-based detectability for a 1 mm calcification embedded in soft tissue. A complementary image-domain contrast-to-noise ratio (CNR) analysis using CT-derived patient anatomy with inserted 1 mm calcifications evaluated CNR as a function of a-Se thickness and dual-energy weighting factor. The CLSM analysis revealed peak task-based detectability at an a-Se thickness of 500-550 um and a tissue-cancellation weighting factor of 1.08. Detectability remained within a few percent of this maximum across a broad range of a-Se thicknesses (300-1000 um). The image-domain CNR analysis yielded maximum CNR at 300 um a-Se and weighting factor of 0.93, with a smaller range of 200-500 um giving acceptable CNR. These results indicate that near-equal weighting of the two detector layers improves anatomical-noise suppression and CAC conspicuity, while a 300 um a-Se top layer provides a practical design compromise between detectability, operating voltage, and manufacturability.
评论: 10 pages, 8 figures
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.00519 [physics.med-ph]
  (或者 arXiv:2611.00519v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.00519

提交历史

来自:Kaitlin Hellier
[v1] 2026年10月31日 星期六 01:14:54 UTC (6,886 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站