跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.26751 (physics)
[提交于 2026年11月19日]

标题:Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants

作者:U-Wai Lok, Jingke Zhang, Jingyi Yin, Lijie Huang, Ryan M. DeRuiter, Yanzhe Zhao, Kaipeng Ji, Tao Wu, Qian Shi, Sanjeev Sethi, Kate M. Knoll, Dawn Boynton, Kathryn A. Robinson, Thomas D. Atwell, Andrew J. Bentall, Chengwu Huang, Shigao Chen
查看论文《Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Three-dimensional ultrasound localization microscopy (3D ULM) enables volumetric visualization of microvasculature beyond the acoustic diffraction limit, but its clinical translation remains limited by long acquisition times, low microbubble (MB) signal-to-noise ratio (SNR), and insufficient MB contrast, particularly on ultrasound systems with a limited number of acquisition channels. In this study, we developed an in-human 3D ULM framework for a 256-channel research ultrasound system equipped with a 1024-element matrix array. The framework combines diverging-wave Hadamard-encoded multipulse (HEM) transmission to enhance MB SNR with denoising strategy combining MB enhancement and four-dimensional non-local means filtering to improve MB contrast. The framework was implemented on a research ultrasound platform and evaluated in phantom experiments and four in vivo human kidney transplants. In phantom experiments, HEM improved the MB contrast ratio around 2 dB, while the proposed denoising strategy enhanced in vivo MB contrast by up to around 9 dB. 3D ULM reconstruction achieved a spatial resolution of approximately 84 um, as estimated by Fourier shell correlation. The number of reconstructed microvascular voxels increased exponentially with acquisition duration, reaching approximately 74% of the estimated saturated vessel density using 3000 volumes (~12 s). The subject with the highest histopathological injury exhibited quantitatively reduced microvascular vessel density, flow velocities, and mean perfusion index. These results demonstrate that the proposed framework enables high-quality volumetric super-resolution imaging and quantitative characterization of renal microvasculature using a 256-channel ultrasound system, providing a practical step toward the clinical translation of in vivo 3D ULM.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.26751 [physics.med-ph]
  (或者 arXiv:2611.26751v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.26751

提交历史

来自:Jingke Zhang
[v1] 2026年11月19日 星期四 19:46:44 UTC (1,635 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站