物理学 > 仪器与探测器
[提交于 2008年11月26日]
标题:The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.
提交历史
来自:Michael Rijssenbeek[v1] 2008年11月26日 星期三 00:00:00 UTC