跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

统计学 > 方法论

arXiv:0903.1880 (stat)
[提交于 2009年3月11日]

标题:SMART: A statistical framework for optimal design matrix generation with application to fMRI

作者:Gautam Pendse, Adam Schwarz, Richard Baumgartner, Alexandre Coimbra, David Borsook, Lino Becerra
查看论文《SMART: A statistical framework for optimal design matrix generation with application to fMRI》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The general linear model (GLM) is a well established tool for analyzing functional magnetic resonance imaging (fMRI) data. Most fMRI analyses via GLM proceed in a massively univariate fashion where the same design matrix is used for analyzing data from each voxel. A major limitation of this approach is the locally varying nature of signals of interest as well as associated confounds. This local variability results in a potentially large bias and uncontrolled increase in variance for the contrast of interest. The main contributions of this paper are two fold (1) We develop a statistical framework called SMART that enables estimation of an optimal design matrix while explicitly controlling the bias variance decomposition over a set of potential design matrices and (2) We develop and validate a numerical algorithm for computing optimal design matrices for general fMRI data sets. The implications of this framework include the ability to match optimally the magnitude of underlying signals to their true magnitudes while also matching the "null" signals to zero size thereby optimizing both the sensitivity and specificity of signal detection. By enabling the capture of multiple profiles of interest using a single contrast (as opposed to an F-test) in a way that optimizes for both bias and variance enables the passing of first level parameter estimates and their variances to the higher level for group analysis which is not possible using F-tests. We demonstrate the application of this approach to in vivo pharmacological fMRI data capturing the acute response to a drug infusion, to task-evoked, block design fMRI and to the estimation of a haemodynamic response function (HRF) response in event-related fMRI. Our framework is quite general and has potentially wide applicability to a variety of disciplines.
评论: 68 pages, 34 figures
主题: 方法论 (stat.ME); 应用 (stat.AP); 计算 (stat.CO)
引用方式: arXiv:0903.1880 [stat.ME]
  (或者 arXiv:0903.1880v1 [stat.ME] 对于此版本)
  https://doi.org/10.48550/arXiv.0903.1880
相关 DOI: https://doi.org/10.1109/TMI.2010.2044512

提交历史

来自:Gautam Pendse
[v1] 2009年3月11日 星期三 19:23:34 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

stat.ME
< 上一篇   |   下一篇 >
最新 | 近期 | 2009-03
切换浏览方式为:
stat
stat.AP
stat.CO

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站