标题:Detrended Fluctuation Analysis of Systolic Blood Pressure Control Loop
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We use detrended fluctuation analysis (DFA) to study the dynamics of blood pressure oscillations and its feedback control in rats by analyzing systolic pressure time series before and after a surgical procedure that interrupts its control loop. We found, for each situation, a crossover between two scaling regions characterized by exponents that reflect the nature of the feedback control and its range of operation. In addition, we found evidences of adaptation in the dynamics of blood pressure regulation a few days after surgical disruption of its main feedback circuit. Based on the paradigm of antagonistic, bipartite (vagal and sympathetic) action of the central nerve system, we propose a simple model for pressure homeostasis as the balance between two nonlinear opposing forces, successfully reproducing the crossover observed in the DFA of actual pressure signals.
提交历史
来自:Carlos Eduardo Galhardo[v1] 2009年8月25日 星期二 13:12:10 UTC