[提交于 2010年5月2日]

标题:Minimal Protocol for MRS Quality Control and Acceptance Test for Philips-Achieva MRS Tool

作者:Stefania Nicolosi, Giorgio Russo, Aldo Zucchetto, Giuseppe Vicari, Ildebrando D'Angelo, Domenico Messana, Maria Carla Gilardi, Paola Scifo
查看论文《Minimal Protocol for MRS Quality Control and Acceptance Test for Philips-Achieva MRS Tool》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Difficulties in obtaining good phantoms, improvements in technologies of voxel localization, better sequences for water and fat suppression has brought us to define a minimal Protocol of home-made quality controls of MRS systems. Measurements, defined in the proposed protocol, have, as main goal, to establish if peaks quantification predicts realistic concentration values, meaning that, the occurrence of this event is a sufficient condition to declare that MRS system works good. Moreover, stability measurements helps in a correct data understanding. It is, indeed, realistic to think that environmental condition can introduce casual errors in the working good system. Discrepancies in the working good condition, under stochastic variability (environment), have to be related to systematic errors introduced by the set of pre and/or post-processing operations and/or by any forms of MRS bad-working tool that differs from the previous. The quality control minimal protocol has been executed on a Philips-Achieva MRS system utilizing a phantom supplied by the manufacturer. The minimal protocol consists of two steps: reproducibility and performance tests. The reproducibility of the MRS measurements helps in quantifying the stability of the system. The performance test enables to establish if the system is able to reproduce concentrations in a realistic way. In both cases good results have been obtained: fluctuations of measured values are below 9% and quantification of concentration is consistent with the known values.
评论: Technical Report LATO
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1004.1026 [physics.med-ph]
  (或者 arXiv:1004.1026v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1004.1026

提交历史

来自:Stefania Nicolosi
[v1] 2010年5月2日 星期日 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2010-05
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站