天体物理学 > 天体物理仪器与方法
[提交于 2011年1月17日]
标题:Atmospheric time constant with MASS and FADE
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:The approximate nature of the adaptive-optics time constant measurements with MASS is examined. The calibration coefficient C derived from numerical simulations of polychromatic scintillation shows dependence on the height of the turbulence layer, wind speed, and seeing. The previously recommended value of C=1.27 is a good match to typical conditions, while C can vary from 0.6 to 1.6 in other circumstances. For two nights, MASS was compared with the time constant measured with adaptive optics, and the expected agreement was found. We show that the single-layer approximation used in some AO systems to derive the AO time constant can give wrong results. A better approach is to estimate it from the speed of focus variation (the FADE method). The analysis of the speed of scintillation developed recently by V.~Kornilov will lead to more accurate measurements of the AO time constant with MASS.
提交历史
来自:Victor Kornilov[v1] 2011年1月17日 星期一 13:52:36 UTC