跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

定量生物学 > 生物分子

arXiv:1105.0780 (q-bio)
[提交于 2011年5月5日]

标题:Homogeneity tests for Michaelis-Menten curves with application to fluorescence resonance energy transfer data

作者:Amparo Baíllo, Laura Martínez-Muñoz, Mario Mellado
查看论文《Homogeneity tests for Michaelis-Menten curves with application to fluorescence resonance energy transfer data》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Resonance energy transfer methods are in wide use for evaluating protein-protein interactions and protein conformational changes in living cells. Fluorescence resonance energy transfer (FRET) measures energy transfer as a function of the acceptor:donor ratio, generating FRET saturation curves. Modeling these curves by Michaelis-Menten kinetics allows characterization by two parameters, which serve to evaluate apparent affinity between two proteins and to compare this affinity in different experimental conditions. To reduce the effect of sampling variability, several statistical samples of the saturation curve are generated in the same biological conditions. Here we study three procedures to determine whether statistical samples in a collection are homogeneous, in the sense that they are extracted from the same regression model. From the hypothesis testing viewpoint, we considered an F test and a procedure based on bootstrap resampling. The third method analyzed the problem from the model selection viewpoint, and used the Akaike information criterion (AIC). Although we only considered the Michaelis-Menten model, all statistical procedures would be applicable to any other nonlinear regression model. We compared the performance of the homogeneity testing methods in a Monte Carlo study and through analysis in living cells of FRET saturation curves for dimeric complexes of CXCR4, a seven-transmembrane receptor of the G protein-coupled receptor family. We show that the F test, the bootstrap procedure and the model selection method lead in general to similar conclusions, although AIC gave the best results when sample sizes were small, whereas the F test and the bootstrap method were more appropriate for large samples. In practice, all three methods are easy to use simultaneously and show consistency, facilitating conclusions on sample homogeneity.
评论: 26 pages, 2 figures
主题: 生物分子 (q-bio.BM); 定量方法 (q-bio.QM); 应用 (stat.AP)
引用方式: arXiv:1105.0780 [q-bio.BM]
  (或者 arXiv:1105.0780v1 [q-bio.BM] 对于此版本)
  https://doi.org/10.48550/arXiv.1105.0780

提交历史

来自:Amparo Baillo
[v1] 2011年5月5日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

q-bio.BM
< 上一篇   |   下一篇 >
最新 | 近期 | 2011-05
切换浏览方式为:
q-bio
q-bio.QM
stat.AP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站