跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

天体物理学 > 天体物理仪器与方法

arXiv:1105.2502 (astro-ph)
[提交于 2011年5月12日]

标题:Astrometry with the MCAO instrument MAD - An analysis of single-epoch data obtained in the layer-oriented mode

作者:Eva Meyer, Martin Kuerster, Carmelo Arcidiacono, Roberto Ragazzoni, Hans-Walter Rix
查看论文《Astrometry with the MCAO instrument MAD - An analysis of single-epoch data obtained in the layer-oriented mode》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Context: Current instrument developments at the largest telescopes worldwide have provisions for Multi-Conjugated Adaptive Optics (MCAO) modules. The large field of view and more uniform correction provided by these systems is not only highly beneficial for photometric studies but also for astrometric analysis of, e.g., large dense clusters and exoplanet detection and characterization. The Multi-conjugated Adaptive optics Demonstrator (MAD) is the first such instrument and was temporarily installed and tested at the ESO/VLT in 2007. We analyzed two globular cluster data sets in terms of achievable astrometric precision. Data were obtained in the layer-oriented correction mode, one in full MCAO correction mode with two layers corrected (NGC 6388) and the other applying ground-layer correction only (47 Tuc). Aims: We aim at analyzing the first available MCAO imaging data in the layer-oriented mode obtained with the MAD instrument in terms of astrometric precision and stability. Methods: We calculated Strehl maps for each frame in both data sets. Distortion corrections were performed and the astrometric precision was analyzed by calculating mean stellar positions over all frames and by investigation of the positional residuals present in each frame after transformation to a master-coordinate-frame. Results: The mean positional precision for stars between K = 14-18 mag is ~1.2 mas in the full MCAO correction mode data of the cluster NGC 6388. The precision measured in the GLAO data (47 Tuc) reaches ~1.0 mas for stars corresponding to 2MASS K magnitudes between 9 and 12. The observations were such that stars in these magnitude ranges correspond to the same detector flux range. The jitter movement used to scan a larger field of view introduced additional distortions in the frames, leading to a degradation of the achievable precision.
评论: 11 pages, 6 figures, accepted for publication in Astronomy & Astrophysics
主题: 天体物理仪器与方法 (astro-ph.IM); 太阳与恒星天体物理学 (astro-ph.SR)
引用方式: arXiv:1105.2502 [astro-ph.IM]
  (或者 arXiv:1105.2502v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1105.2502
相关 DOI: https://doi.org/10.1051/0004-6361/201016053

提交历史

来自:Eva Meyer
[v1] 2011年5月12日 星期四 15:17:59 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2011-05
切换浏览方式为:
astro-ph
astro-ph.SR

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站