标题:GPU-based fast Monte Carlo simulation for radiotherapy dose calculation

作者:Xun Jia, Xuejun Gu, Yan Jiang Graves, Michael Folkerts, Steve B. Jiang
查看论文《GPU-based fast Monte Carlo simulation for radiotherapy dose calculation》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our recent progress towards the development a GPU-based MC dose calculation package, gDPM v2.0. It utilizes the parallel computation ability of a GPU to achieve high efficiency, while maintaining the same particle transport physics as in the original DPM code and hence the same level of simulation accuracy. In GPU computing, divergence of execution paths between threads can considerably reduce the efficiency. Since photons and electrons undergo different physics and hence attain different execution paths, we use a simulation scheme where photon transport and electron transport are separated to partially relieve the thread divergence issue. High performance random number generator and hardware linear interpolation are also utilized. We have also developed various components to handle fluence map and linac geometry, so that gDPM can be used to compute dose distributions for realistic IMRT or VMAT treatment plans. Our gDPM package is tested for its accuracy and efficiency in both phantoms and realistic patient cases. In all cases, the average relative uncertainties are less than 1%. A statistical t-test is performed and the dose difference between the CPU and the GPU results is found not statistically significant in over 96% of the high dose region and over 97% of the entire region. Speed up factors of 69.1 ~ 87.2 have been observed using an NVIDIA Tesla C2050 GPU card against a 2.27GHz Intel Xeon CPU processor. For realistic IMRT and VMAT plans, MC dose calculation can be completed with less than 1% standard deviation in 36.1~39.6 sec using gDPM.
评论: 18 pages, 5 figures, and 3 tables
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1107.3355 [physics.med-ph]
  (或者 arXiv:1107.3355v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1107.3355
相关 DOI: https://doi.org/10.1088/0031-9155/56/22/002

提交历史

来自:Xun Jia
[v1] 2011年7月18日 星期一 05:10:24 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2011-07
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站