跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:1107.3427 (physics)
[提交于 2011年7月18日]

标题:Measurement of probe displacement to the thermal resolution limit in photonic force microscopy using a miniature quadrant photodetector

作者:Sambit Bikas Pal, Arijit Haldar, Basudev Roy, Ayan Banerjee
查看论文《Measurement of probe displacement to the thermal resolution limit in photonic force microscopy using a miniature quadrant photodetector》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A photonic force microscope comprises of an optically trapped micro-probe and a position detection system to track the motion of the probe. Signal collection for motion detection is often carried out using the backscattered light off the probe - however, this mode has problems of low S/N due to the small back-scattering cross-sections of the micro-probes typically used. The position sensors often used in these cases are quadrant photodetectors. To ensure maximum sensitivity of such detectors, it would help if the detector size matched with the detection beam radius after the condenser lens (which for backscattered detection would be the trapping objective itself). To suit this condition, we have used a miniature displacement sensor whose dimensions makes it ideal to work with 1:1 images of micron-sized trapped probes in the back-scattering detection mode. The detector is based on the quadrant photo-IC in the optical pick-up head of a compact disc player. Using this detector, we measured absolute displacements of an optically trapped 1.1 um probe with a resolution of ~10 nm for a bandwidth of 10 Hz at 95% significance without any sample or laser stabilization. We characterized our optical trap for different sized probes by measuring the power spectrum for each probe to 1% accuracy, and found that for 1.1 um diameter probes, the noise in our position measurement matched the thermal resolution limit for averaging times up to 10 ms. We also achieved a linear response range of around 385 nm with crosstalk between axes ~4% for 1.1 um diameter probes. The detector has extremely high bandwidth (few MHz) and low optical power threshold - other factors that can lead to it's widespread use in photonic force microscopy.
评论: 11 pages, 11 figures
主题: 仪器与探测器 (physics.ins-det); 光学 (physics.optics)
引用方式: arXiv:1107.3427 [physics.ins-det]
  (或者 arXiv:1107.3427v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1107.3427
相关 DOI: https://doi.org/10.1063/1.3685616

提交历史

来自:Ayan Banerjee
[v1] 2011年7月18日 星期一 13:20:13 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2011-07
切换浏览方式为:
physics
physics.optics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站