电气工程与系统科学 > 系统与控制
[提交于 2011年8月4日]
标题:Analysis, Dimensioning and Robust Control of Shunt Active Filter for Harmonic Currents Compensation in Electrical Mains
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:In this chapter some results related to Shunt Active Filters (SAFs) and obtained by the authors and some coauthors are reported. SAFs are complex power electronics equipments adopted to compensate for cur-rent harmonic pollution in electric mains, due to nonlinear loads. By using a proper "floating" capacitor as energy reservoir, the SAF purpose is to inject in the line grid currents canceling the polluting har-monics. Control algorithms play a key role for such devices and, in general, in many power electronics applications. Moreover, systems theory is crucial, since it is the mathematical tool that enables a deep understanding of the involved dynamics of such systems, allowing a correct dimensioning, beside an effective control. As a matter of facts, current injection objective can be straightforwardly formulated as an output tracking control problem. In this fashion, the structural and insidious marginally-stable internal/zero dynamics of SAFs can be immediately highlighted and characterized in terms of sizing and control issues. For what concerns the control design strictly, time-scale separation among output and internal dynamics can be effectively exploited to split the control design in different stages that can be later aggregated, by using singular perturbation analysis. In addition, for robust asymptotic output tracking the Internal Model Principle is adopted.
提交历史
来自:Christian Conficoni[v1] 2011年8月4日 星期四 15:46:29 UTC