物理学 > 原子物理
[提交于 2011年8月22日]
标题:Compact Frequency Standard Based on an Intra-cavity Sample Cold Cesium Atoms
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We have demonstrated the possibility for a compact frequency standard based on a sample of cold cesium atoms. In a cylindrical microwave cavity, the atoms are cooled and interrogated during a free expansion and then detected. The operation of this experiment is different from conventional atomic fountains, since all the steps are sequentially performed in the same position of space. In this paper we report the analysis of a Ramsey pattern observed to present a 47 Hz linewidth and a stability of 5x10^-13 for an integration time longer than 100s. Some of the main limitations of the standard are analyzed. This present report demonstrates considerable improvement of our previous work (S. T. Muller et al, J. Opt. Soc. Am. B, v.25, p.909, 2008) where the atoms were in a free space and not inside a microwave cavity.
提交历史
来自:Stella Muller Dr[v1] 2011年8月22日 星期一 19:58:50 UTC