标题:Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3E-16, with a frequency bias of 0.4E-16. The agreement between the measurements and calculations explains the previously observed frequency shifts at elevated microwave amplitude. We also evaluate the frequency bias and uncertainty due to the microwave lensing of the atomic wavepackets. We report a total PTB-CSF2 systematic uncertainty of 4.1E-16.
提交历史
来自:Stefan Weyers[v1] 2011年10月12日 星期三 08:07:26 UTC