跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 核实验

arXiv:1202.2238 (nucl-ex)
[提交于 2012年2月10日]

标题:Medical Application Studies at ELI-NP

作者:D. Habs, P. G. Thirolf, C. Lang, M. Jentschel, U. Köster, F. Negoita, V. Zamfir
查看论文《Medical Application Studies at ELI-NP》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We study the production of radioisotopes for nuclear medicine in (gamma,gamma') photoexcitation reactions or (gamma,xn + yp) photonuclear reactions for the examples of ^195mPt, ^117mSn and ^44Ti with high flux [(10^13 - 10^15) gamma/s], small beam diameter and small energy band width (Delta E/E ~ 10^-3 -10^-4) gamma beams. In order to realize an optimum gamma-focal spot, a refractive gamma-lens consisting of a stack of many concave micro-lenses will be used. It allows for the production of a high specific activity and the use of enriched isotopes. For photonuclear reactions with a narrow gamma beam, the energy deposition in the target can be reduced by using a stack of thin target wires, hence avoiding direct stopping of the Compton electrons and e^+e^- pairs. The well-defined initial excitation energy of the compound nucleus leads to a small number of reaction channels and enables new combinations of target isotope and final radioisotope. The narrow-bandwidth gamma excitation may make use of collective resonances in gamma-width, leading to increased cross sections. (gamma,gamma') isomer production via specially selected gamma cascades allows to produce high specific activity in multiple excitations, where no back-pumping of the isomer to the ground state occurs. The produced isotopes will open the way for completely new clinical applications of radioisotopes. For example ^195mPt could be used to verify the patient's response to chemotherapy with platinum compounds before a complete treatment is performed. In targeted radionuclide therapy the short-range Auger and conversion electrons of ^195mPt and ^117mSn enable a very local treatment. The generator ^44Ti allows for a PET with an additional gamma-quantum (gamma-PET), resulting in a reduced dose or better spatial resolution.
评论: 10 pages, 7 figures
主题: 核实验 (nucl-ex)
引用方式: arXiv:1202.2238 [nucl-ex]
  (或者 arXiv:1202.2238v1 [nucl-ex] 对于此版本)
  https://doi.org/10.48550/arXiv.1202.2238

提交历史

来自:Peter Thirolf
[v1] 2012年2月10日 星期五 11:36:12 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

nucl-ex
< 上一篇   |   下一篇 >
最新 | 近期 | 2012-02

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站