arXiv:1203.0918 (physics)
[提交于 2015年6月4日]

标题:Accounting for the thickness effect in dynamic spherical indentation of a viscoelastic layer: Application to non-destructive testing of articular cartilage

作者:I. Argatov, A. U. Daniels, G. Mishuris, S. Ronken, D. Wirz
查看论文《Accounting for the thickness effect in dynamic spherical indentation of a viscoelastic layer: Application to non-destructive testing of articular cartilage》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:In recent years, dynamic indentation tests have been shown to be useful both in identification of mechanical properties of biological tissues (such as articular cartilage) and assessing their viability. We consider frictionless flat-ended and spherical sinusoidally-driven indentation tests utilizing displacement-controlled loading protocol. Articular cartilage tissue is modeled as a viscoelastic material with a time-independent Poisson's ratio. We study the dynamic indentation stiffness with the aim of formulating criteria for evaluation the quality of articular cartilage in order to be able to discriminate its degenerative state. In particular, evaluating the dynamic indentation stiffness at the turning point of the flat-ended indentation test, we introduce the so-called incomplete storage modulus. Considering the time difference between the time moments when the dynamic stiffness vanishes (contact force reaches its maximum) and the dynamic stiffness becomes infinite (indenter displacement reaches its maximum), we introduce the so-called incomplete loss angle. Analogous quantities can be introduced in the spherical sinusoidally-driven indentation test, however, to account for the thickness effect, a special approach is required. We apply an asymptotic modeling approach for analyzing and interpreting the results of the dynamic spherical indentation test in terms of the geometrical parameter of the indenter and viscoelastic characteristics of the material. Some implications to non-destructive indentation diagnostics of cartilage degeneration are discussed.
评论: 29 pages, 7 Figures
主题: 生物物理 (physics.bio-ph)
引用方式: arXiv:1203.0918 [physics.bio-ph]
  (或者 arXiv:1203.0918v1 [physics.bio-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1203.0918
相关 DOI: https://doi.org/10.1016/j.euromechsol.2012.07.004

提交历史

来自:Gennady Mishuris
[v1] 2015年6月4日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.bio-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2015-06
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站