跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

天体物理学 > 天体物理仪器与方法

arXiv:1204.2381 (astro-ph)
[提交于 2012年4月11日]

标题:Terahertz hot electron bolometer waveguide mixers for GREAT

作者:P. Pütz, C. E. Honingh, K. Jacobs, M. Justen, M. Schultz, J. Stutzki
查看论文《Terahertz hot electron bolometer waveguide mixers for GREAT》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Supplementing the publications based on the first-light observations with the German Receiver for Astronomy at Terahertz frequencies (GREAT) on SOFIA, we present background information on the underlying heterodyne detector technology. We describe the superconducting hot electron bolometer (HEB) detectors that are used as frequency mixers in the L1 (1400 GHz), L2 (1900 GHz), and M (2500 GHz) channels of GREAT. Measured performance of the detectors is presented and background information on their operation in GREAT is given. Our mixer units are waveguide-based and couple to free-space radiation via a feedhorn antenna. The HEB mixers are designed, fabricated, characterized, and flight-qualified in-house. We are able to use the full intermediate frequency bandwidth of the mixers using silicon-germanium multi-octave cryogenic low-noise amplifiers with very low input return loss. Superconducting HEB mixers have proven to be practical and sensitive detectors for high-resolution THz frequency spectroscopy on SOFIA. We show that our niobium-titanium-nitride (NbTiN) material HEBs on silicon nitride (SiN) membrane substrates have an intermediate frequency (IF) noise roll-off frequency above 2.8 GHz, which does not limit the current receiver IF bandwidth. Our mixer technology development efforts culminate in the first successful operation of a waveguide-based HEB mixer at 2.5 THz and deployment for radioastronomy. A significant contribution to the success of GREAT is made by technological development, thorough characterization and performance optimization of the mixer and its IF interface for receiver operation on SOFIA. In particular, the development of an optimized mixer IF interface contributes to the low passband ripple and excellent stability, which GREAT demonstrated during its initial successful astronomical observation runs.
评论: Accepted for publication in A&A (SOFIA/GREAT special issue)
主题: 天体物理仪器与方法 (astro-ph.IM)
引用方式: arXiv:1204.2381 [astro-ph.IM]
  (或者 arXiv:1204.2381v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1204.2381
相关 DOI: https://doi.org/10.1051/0004-6361/201218916

提交历史

来自:Patrick Pütz
[v1] 2012年4月11日 星期三 09:20:32 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2012-04
切换浏览方式为:
astro-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站