天体物理学 > 天体物理仪器与方法
[提交于 2012年7月11日]
标题:Generic Misalignment Aberration Patterns and the Subspace of Benign Misalignment
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Q1: Why deploy N wavefront sensors on a three mirror anastigmat (TMA) and not N + 1? Q2: Why measure M Zernike coefficients and not M + 1? Q3: Why control L rigid body degrees of freedom (total) on the secondary and tertiary and not L + 1? The usual answer: "We did a lot of ray tracing and N,M, and L seemed OK." We show how straightforward results from aberration theory may be used to address these questions. We consider, in particular, the case of a three mirror anastigmat.
提交历史
来自:Rebecca Sobel[v1] 2012年7月11日 星期三 14:19:10 UTC