跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 计算机视觉与模式识别

arXiv:1207.3370 (cs)
[提交于 2012年7月13日]

标题:Deconvolution of vibroacoustic images using a simulation model based on a three dimensional point spread function

作者:Talita Perciano, Matthew Urban, Nelson D. A. Mascarenhas, Mostafa Fatemi, Alejandro C. Frery, Glauber T. Silva
查看论文《Deconvolution of vibroacoustic images using a simulation model based on a three dimensional point spread function》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Vibro-acoustography (VA) is a medical imaging method based on the difference-frequency generation produced by the mixture of two focused ultrasound beams. VA has been applied to different problems in medical imaging such as imaging bones, microcalcifications in the breast, mass lesions, and calcified arteries. The obtained images may have a resolution of 0.7--0.8 mm. Current VA systems based on confocal or linear array transducers generate C-scan images at the beam focal plane. Images on the axial plane are also possible, however the system resolution along depth worsens when compared to the lateral one. Typical axial resolution is about 1.0 cm. Furthermore, the elevation resolution of linear array systems is larger than that in lateral direction. This asymmetry degrades C-scan images obtained using linear arrays. The purpose of this article is to study VA image restoration based on a 3D point spread function (PSF) using classical deconvolution algorithms: Wiener, constrained least-squares (CLSs), and geometric mean filters. To assess the filters' performance, we use an image quality index that accounts for correlation loss, luminance and contrast distortion. Results for simulated VA images show that the quality index achieved with the Wiener filter is 0.9 (1 indicates perfect restoration). This filter yielded the best result in comparison with the other ones. Moreover, the deconvolution algorithms were applied to an experimental VA image of a phantom composed of three stretched 0.5 mm wires. Experiments were performed using transducer driven at two frequencies, 3075 kHz and 3125 kHz, which resulted in the difference-frequency of 50 kHz. Restorations with the theoretical line spread function (LSF) did not recover sufficient information to identify the wires in the images. However, using an estimated LSF the obtained results displayed enough information to spot the wires in the images.
评论: Accepted for publication in Ultrasonics
主题: 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:1207.3370 [cs.CV]
  (或者 arXiv:1207.3370v1 [cs.CV] 对于此版本)
  https://doi.org/10.48550/arXiv.1207.3370
相关 DOI: https://doi.org/10.1016/j.ultras.2012.03.011

提交历史

来自:Alejandro Frery
[v1] 2012年7月13日 星期五 21:37:04 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CV
< 上一篇   |   下一篇 >
最新 | 近期 | 2012-07
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站