跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 信息论

arXiv:1209.2262 (cs)
[提交于 2012年9月11日]

标题:A single-photon sampling architecture for solid-state imaging

作者:Ewout van den Berg, Emmanuel Candes, Garry Chinn, Craig Levin, Peter Olcott, Carlos Sing-Long
查看论文《A single-photon sampling architecture for solid-state imaging》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Advances in solid-state technology have enabled the development of silicon photomultiplier sensor arrays capable of sensing individual photons. Combined with high-frequency time-to-digital converters (TDCs), this technology opens up the prospect of sensors capable of recording with high accuracy both the time and location of each detected photon. Such a capability could lead to significant improvements in imaging accuracy, especially for applications operating with low photon fluxes such as LiDAR and positron emission tomography. The demands placed on on-chip readout circuitry imposes stringent trade-offs between fill factor and spatio-temporal resolution, causing many contemporary designs to severely underutilize the technology's full potential. Concentrating on the low photon flux setting, this paper leverages results from group testing and proposes an architecture for a highly efficient readout of pixels using only a small number of TDCs, thereby also reducing both cost and power consumption. The design relies on a multiplexing technique based on binary interconnection matrices. We provide optimized instances of these matrices for various sensor parameters and give explicit upper and lower bounds on the number of TDCs required to uniquely decode a given maximum number of simultaneous photon arrivals. To illustrate the strength of the proposed architecture, we note a typical digitization result of a 120x120 photodiode sensor on a 30um x 30um pitch with a 40ps time resolution and an estimated fill factor of approximately 70%, using only 161 TDCs. The design guarantees registration and unique recovery of up to 4 simultaneous photon arrivals using a fast decoding algorithm. In a series of realistic simulations of scintillation events in clinical positron emission tomography the design was able to recover the spatio-temporal location of 98.6% of all photons that caused pixel firings.
评论: 24 pages, 3 figures, 5 tables
主题: 信息论 (cs.IT); 信息论 (math.IT); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:1209.2262 [cs.IT]
  (或者 arXiv:1209.2262v1 [cs.IT] 对于此版本)
  https://doi.org/10.48550/arXiv.1209.2262
相关 DOI: https://doi.org/10.1073/pnas.1216318110

提交历史

来自:Ewout van den Berg
[v1] 2012年9月11日 星期二 09:04:17 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.IT
< 上一篇   |   下一篇 >
最新 | 近期 | 2012-09
切换浏览方式为:
cs
math.IT
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站