跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 其他计算机科学

arXiv:1212.6241 (cs)
[提交于 2012年12月21日]

标题:Building design in tropical climates. Elaboration of the ECODOM standard in the french tropical islands

作者:François Garde, Harry Boyer, Robert Celaire, Laurent Seauve
查看论文《Building design in tropical climates. Elaboration of the ECODOM standard in the french tropical islands》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:This paper deals with the elaboration of global quality standards for natural and low energy cooling in french tropical island buildings. Electric load profiles of tropical islands in developed countries are characterised by morning, midday and evening peaks arising from all year round high power demand in the commercial and residential sectors, mostly due to air conditioning appliances and bad thermal conception of the building. In early 1995, a DSM pilot initiative has been launched in the french islands of Guadeloupe and Reunion through a partnership between the French Public Utility EDF, institutions involved in energy conservation, environment preservation (ADEME) and construction quality improvment, the University of Reunion Island and several other public and private partners (low cost housing institutions, architects, energy consultant, etc...) to set up a standard in the thermal conception of buildings in tropical climates. This has led to definition of optimized bioclimatic urban planning and architectural design, the use of passive cooling architectural components, natural ventilation and energy efficient systems. The impact of each technical solution on the thermal comfort within the building was evaluated with an airflow and thermal building simulation software (CODYRUN). These technical solutions have been edited in a pedagogical reference document and have been implemented in 300 new pilot dwelling projects through the year 1996 in Reunion Island and in Guadeloupe island. An experimental follow up is still in process in the first ECODOM dwellings for an experimental validation of the impact of the passive cooling solutions on the comfort of the occupants and to modify them if necessary.
评论: ISES'99, International Solar Energy Society, J\'erusalem : Israel (1999). arXiv admin note: substantial text overlap with arXiv:1212.3925, arXiv:1212.5252
主题: 其他计算机科学 (cs.OH)
引用方式: arXiv:1212.6241 [cs.OH]
  (或者 arXiv:1212.6241v1 [cs.OH] 对于此版本)
  https://doi.org/10.48550/arXiv.1212.6241

提交历史

来自:Harry Boyer
[v1] 2012年12月21日 星期五 18:54:26 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.OH
< 上一篇   |   下一篇 >
最新 | 近期 | 2012-12
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站