物理学 > 仪器与探测器
[提交于 2013年4月28日]
标题:Coupler Conditioning and High Power Testing of ADS Spoke Cavity
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Power couplers, used in China-ADS proton linac injector I, are required to transfer 6kW RF power to the superconducting Spoke cavities. At present, first two couplers of coaxial design have been fabricated and accomplished high power test at IHEP. The test results indicated that couplers of this design are qualified to deliver 10kW RF power in continuous travelling wave mode. This paper described the coupler's room temperature test procedures and results, discussed the original high power test terminated due to serious out-gassing and after some modifications. In the final test, the couplers smoothly exceeded the design power level.
提交历史
来自:Xu Chen[v1] 2013年4月28日 星期日 03:00:55 UTC