跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 数学物理

arXiv:1306.0265 (math-ph)
[提交于 2014年12月23日]

标题:Multi-frequency subspace migration for imaging of perfectly conducting, arc-like cracks

作者:Won-Kwang Park
查看论文《Multi-frequency subspace migration for imaging of perfectly conducting, arc-like cracks》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Multi-frequency subspace migration imaging technique are usually adopted for the non-iterative imaging of unknown electromagnetic targets such as cracks in the concrete walls or bridges, anti-personnel mines in the ground, etc. in the inverse scattering problems. It is confirmed that this technique is very fast, effective, robust, and can be applied not only full- but also limited-view inverse problems if suitable number of incident and corresponding scattered field are applied and collected. But in many works, the application of such technique is somehow heuristic. Under the motivation of such heuristic application, this contribution analyzes the structure of imaging functional employed in the subspace migration imaging technique in two-dimensional inverse scattering when the unknown target is arbitrary shaped, arc-like perfectly conducting cracks located in the homogeneous two-dimensional space. Opposite to the Statistical approach based on the Statistical Hypothesis Testing, our approach is based on the fact that subspace migration imaging functional can be expressed by a linear combination of Bessel functions of integer order of the first kind. This is based on the structure of the Multi-Static Response (MSR) matrix collected in the far-field at nonzero frequency in either Transverse Magnetic (TM) mode or Transverse Electric (TE) mode. Explored expression of imaging functionals gives us certain properties of subspace migration and an answer of why multi-frequency enhances imaging resolution. Particularly, we carefully analyze the subspace migration and confirm some properties of imaging when a small number of incident field is applied. Consequently, we simply introduce a weighted multi-frequency imaging functional and confirm that which is an improved version of subspace migration in TM mode.
评论: 42 pages, 41 figures
主题: 数学物理 (math-ph); 数学物理 (math.MP)
引用方式: arXiv:1306.0265 [math-ph]
  (或者 arXiv:1306.0265v1 [math-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1306.0265
期刊参考: J. Comput. Phys., 283, 52-80, 2015
相关 DOI: https://doi.org/10.1016/j.jcp.2014.11.036

提交历史

来自:Won-Kwang Park
[v1] 2014年12月23日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

math-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2014-12
切换浏览方式为:
math.MP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站