物理学 > 仪器与探测器
[提交于 2015年12月9日]
标题:Design of the MiniCLEAN dark matter search veto detector subsystem
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:This paper describes the design of the active muon veto subsystem for the MiniCLEAN dark matter direct detection experiment at SNOLAB in Sudbury, Ontario, Canada. The water-filled veto is instrumented with 48 PMTs which are read out by front end electronics to time multiplex 48 photomultiplier channels into 6 digitizer channels and provide an instantaneous hit sum across the subsystem (N-Hit) for the veto trigger. We describe the primary system components: the PMTs, the support structure, the front-end electronics, and the data acquisition system.
提交历史
来自:Benjamin Buck[v1] 2015年12月9日 星期三 00:00:00 UTC