定量生物学 > 定量方法
[提交于 2014年3月24日]
标题:Propagation of Uncertainty and Analysis of Signal-to-Noise in Nonlinear Compliance Estimations of an Arterial System Model
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:The arterial system dynamically loads the heart through changes in arterial compliance. The pressure-volume relation of arteries is known to be nonlinear, but arterial compliance is often modeled as a constant value, due to ease of estimation and interpretation. Incorporating nonlinear arterial compliance affords insight into the continuous variations of arterial compliance in a cardiac cycle and its effects on the heart, as the arterial system is coupled with the left ventricle. We recently proposed a method for estimating nonlinear compliance parameters that yielded good results under various vasoactive states. This study examines the performance of the proposed method by quantifying the uncertainty of the method in the presence of noise and propagating the uncertainty through the system model to analyze its effects on model predictions. Kernel density estimation used within a bootstrap Monte Carlo simulation showed the method to be stable for various vasoactive states.
提交历史
来自:Timothy Phan[v1] 2014年3月24日 星期一 22:24:57 UTC