跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1407.0667 (physics)
[提交于 2017年2月8日]

标题:A method for real-time volumetric imaging in radiotherapy using single x-ray projection

作者:Yuan Xu, Hao Yan, Luo Ouyang, Jing Wang, Linghong Zhou, Laura Cervino, Steve B. Jiang, Xun Jia
查看论文《A method for real-time volumetric imaging in radiotherapy using single x-ray projection》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:In this paper, we present a new method to generate an instantaneous volumetric image using a single x-ray projection. To fully extract motion information hidden in projection images, we partitioned a projection image into small patches. We utilized a sparse learning method to automatically select patches that have a high correlation with principal component analysis (PCA) coefficients of a lung motion model. A model that maps the patch intensity to the PCA coefficients is built along with the patch selection process. Based on this model, a measured projection can be used to predict the PCA coefficients, which are further used to generate a motion vector field and hence a volumetric image. We have also proposed an intensity baseline correction method based on the partitioned projection, where the first and the second moments of pixel intensities at a patch in a simulated image are matched with those in a measured image via a linear transformation. The proposed method has been valid in simulated data and real phantom data. The algorithm is able to identify patches that contain relevant motion information, e.g. diaphragm region. It is found that intensity correction step is important to remove the systematic error in the motion prediction. For the simulation case, the sparse learning model reduced prediction error for the first PCA coefficient to 5%, compared to the 10% error when sparse learning is not used. 95th percentile error for the predicted motion vector is reduced from 2.40 mm to 0.92mm. In the phantom case, the predicted tumor motion trajectory is successfully reconstructed with 0.82 mm mean vector field error compared to 1.66 mm error without using the sparse learning method. The algorithm robustness with respect to sparse level, patch size, and existence of diaphragm, as well as computation time, has also been studied.
评论: 20 pages, 9 figures
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1407.0667 [physics.med-ph]
  (或者 arXiv:1407.0667v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1407.0667
相关 DOI: https://doi.org/10.1118/1.4918577

提交历史

来自:Xun Jia
[v1] 2017年2月8日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-02
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站