标题:Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR-brachytherapy

作者:Bram L. Gorissen, Dick den Hertog, Aswin L. Hoffmann
查看论文《Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR-brachytherapy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Current inverse treatment planning methods that optimize both catheter positions and dwell times in prostate HDR brachytherapy use surrogate linear or quadratic objective functions that have no direct interpretation in terms of dose-volume histogram (DVH) criteria, do not result in an optimum or have long solution times. We decrease the solution time of existing linear and quadratic dose-based programming models (LP and QP, respectively) to allow optimizing over potential catheter positions using mixed integer programming. An additional average speed-up of 75% can be obtained by stopping the solver at an early stage, without deterioration of the plan quality. For a fixed catheter configuration, the dwell time optimization model LP solves to optimality in less than 15 seconds, which confirms earlier results. We propose an iterative procedure for QP that allows to prescribe the target dose as an interval, while retaining independence between the solution time and the number of dose calculation points. This iterative procedure is comparable in speed to the LP model, and produces better plans than the non-iterative QP. We formulate a new dose-volume based model that maximizes $V_{100\%}$ while satisfying pre-set DVH-criteria. This model optimizes both catheter positions and dwell times within a few minutes depending on prostate volume and number of catheters, optimizes dwell times within 35 seconds, and gives better DVH statistics than dose-based models. The solutions suggest that the correlation between objective value and clinical plan quality is weak in existing dose-based models.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1408.2746 [physics.med-ph]
  (或者 arXiv:1408.2746v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1408.2746
期刊参考: Physics in Medicine and Biology, 58(4), 1041-1058, 2013
相关 DOI: https://doi.org/10.1088/0031-9155/58/4/1041

提交历史

来自:Bram L Gorissen
[v1] 2014年8月12日 星期二 15:31:56 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2014-08
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站