跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 系统与控制

arXiv:1408.6595 (eess)
[提交于 2014年8月27日]

标题:A comparison of non-intrusive load monitoring methods for commercial and residential buildings

作者:Nipun Batra, Oliver Parson, Mario Berges, Amarjeet Singh, Alex Rogers
查看论文《A comparison of non-intrusive load monitoring methods for commercial and residential buildings》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Non intrusive load monitoring (NILM), or energy disaggregation, is the process of separating the total electricity consumption of a building as measured at single point into the building's constituent loads. Previous research in the field has mostly focused on residential buildings, and although the potential benefits of applying this technology to commercial buildings have been recognised since the field's conception, NILM in the commercial domain has been largely unexplored by the academic community. As a result of the heterogeneity of this section of the building stock (i.e., encompassing buildings as diverse as airports, malls and coffee shops), and hence the loads within them, many of the solutions developed for residential energy disaggregation do not apply directly. In this paper we highlight some insights for NILM in the commercial domain using data collected from a large smart meter deployment within an educational campus in Delhi, India, of which a subset of the data has been released for public use. We present an empirical characterisation of loads in commercial buildings, highlighting the differences in energy consumption and load characteristics between residential and commercial buildings. We assess the validity of the assumptions generally made by NILM solutions for residential buildings when applied to measurements from commercial facilities. Based on our observations, we discuss the required traits for a NILM system for commercial buildings, and run benchmark residential NILM algorithms on our data set to confirm our observations. To advance the research in commercial buildings energy disaggregation, we release a subset of our data set, called COMBED (commercial building energy data set).
主题: 系统与控制 (eess.SY); 系统与控制 (cs.SY)
引用方式: arXiv:1408.6595 [eess.SY]
  (或者 arXiv:1408.6595v1 [eess.SY] 对于此版本)
  https://doi.org/10.48550/arXiv.1408.6595

提交历史

来自:Nipun Batra
[v1] 2014年8月27日 星期三 23:58:19 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SY
< 上一篇   |   下一篇 >
最新 | 近期 | 2014-08
切换浏览方式为:
eess
cs.SY

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站