标题:Calculating tumor trajectory and dose-of-the-day using cone-beam CT projections

作者:Bernard L. Jones, David Westerly, Moyed Miften
查看论文《Calculating tumor trajectory and dose-of-the-day using cone-beam CT projections》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed and validated a method which uses these projections to determine the trajectory of and dose to highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, the trajectory of which mimicked a lung tumor with high amplitude (up to 2.5 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each CBCT projection, and a Gaussian probability density function for the absolute BB position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two modifications of the trajectory reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation (Phase), and second, using the Monte Carlo (MC) method to sample the estimated Gaussian tumor position distribution. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and trajectory errors averaged 3.8$\pm$1.1% of the marker amplitude. Dosimetric calculations using Phase methods were more accurate, with mean absolute error less than 0.5%, and with error less than 1% in the highest-noise trajectory. MC-based trajectories prevent the over-estimation of dose, but when viewed in an absolute sense, add a small amount of dosimetric error (<0.1%). Conclusions: Marker trajectory and target dose-of-the-day were accurately calculated using CBCT projections. This technique provides a method to evaluate highly-mobile tumors using ordinary CBCT data, and could facilitate better strategies to mitigate or compensate for motion during SBRT.
评论: Submitted to Medical Physics journal, 11 pages, 5 figures
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1501.03406 [physics.med-ph]
  (或者 arXiv:1501.03406v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1501.03406
期刊参考: Med. Phys. 42, 694 (2015)
相关 DOI: https://doi.org/10.1118/1.4905107

提交历史

来自:Bernard Jones
[v1] 2015年1月14日 星期三 16:53:41 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2015-01
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站