跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 计算机视觉与模式识别

arXiv:1501.03779 (cs)
[提交于 2015年1月15日]

标题:Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study

作者:Holger R. Roth, Thomas E. Hampshire, Emma Helbren, Mingxing Hu, Roser Vega, Steve Halligan, David J. Hawkes
查看论文《Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.
评论: This paper was presented at the SPIE Medical Imaging 2014 conference
主题: 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:1501.03779 [cs.CV]
  (或者 arXiv:1501.03779v1 [cs.CV] 对于此版本)
  https://doi.org/10.48550/arXiv.1501.03779
期刊参考: Proc. SPIE 9036, Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and Modeling, 903609 (March 12, 2014)
相关 DOI: https://doi.org/10.1117/12.2042860

提交历史

来自:Holger Roth
[v1] 2015年1月15日 星期四 19:11:26 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CV
< 上一篇   |   下一篇 >
最新 | 近期 | 2015-01
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站