物理学 > 流体动力学
[提交于 2015年2月20日]
标题:Air-Gap Convection in a Switched Reluctance Machine
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Switched reluctance machines (SRMs) have recently become popular in the automotive market as they are a good alternative to the permanent magnet machines commonly employed for an electric powertrain. Lumped parameter thermal networks are usually used for thermal analysis of motors due to their low computational cost and relatively accurate results. A critical aspect to be modelled is the rotor-stator air-gap heat transfer, and this is particularly challenging in an SRM due to the salient pole geometry. This work presents firstly a review of the literature including the most relevant correlations for this geometry, and secondly, numerical CFD simulations of air-gap heat transfer for a typical configuration. A new correlation has been derived: $\mathbf{Nu=0.181\ Ta_m^{0.207}}$
提交历史
来自:Pietro Romanazzi[v1] 2015年2月20日 星期五 15:26:14 UTC