跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1506.05152 (physics)
[提交于 2015年6月16日]

标题:Dosimetric and Biologic Differences in Flattened and Flattening-Filter-Free Beam Treatment Plans

作者:Yue Yan, Poonam Yadav, Michael Bassetti, Kaifang Du, Daniel Saenz, Paul Harari, Bhudatt R. Paliwal
查看论文《Dosimetric and Biologic Differences in Flattened and Flattening-Filter-Free Beam Treatment Plans》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To quantitatively compare the dosimetric and biologic differences in treatment plans from flattened and flattening-filter-free (FFF) beam for three anatomic cancer sites. Methods and Materials: Treatment plans with static intensity-modulated radiotherapy beams and volumetric modulated arc therapy beams were generated for 13 patients for both the flattened beam and the FFF beam of the TrueBeam system. Beam energies of 6 MV and 10 MV were chosen for planning. A total of 104 treatment plans were generated in 13 patients. In order to analyze the biological effectiveness of treatment plans, dose volume histograms (DVH) were utilized. Flattened and FFF beam plans are quantitatively compared. Results: In head and neck cases, for VMAT plans, dose reduction in the FFF beam plans compared to the flattened beam in left cochlea, right submandibular gland and right parotid gland reached up to 2.36 Gy, 1.21 Gy and 1.45 Gy, respectively. Similarly, for static IMRT plans, the dose reduction of the FFF beam plans compared to the flattened beam plans for the same organs reached up to 0.34 Gy, 1.36 Gy and 1.46 Gy, respectively. Overall, for head and neck, the FFF beam plans achieved mean dose reduction of up to 5%, 7% and 9%, respectively for above organs at risk. For lung and prostate cases, the FFF beams provided lower or comparable NTCP values to organ-at-risk (OAR) compared to the flattened beam for all plans. Conclusions: In general, we observed treatment plans utilizing FFF beams can improve dose sparing to OARs without compromising the target coverage. Significant dose sparing effect is obtained for head and neck cancer cases, especially for the cases with relatively large field sizes (about 16x20 cm^2). For lung and prostate cases, compared to the flattened beam, the FFF beam based treatment plans provide lower or comparable dose to most OARs.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1506.05152 [physics.med-ph]
  (或者 arXiv:1506.05152v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1506.05152

提交历史

来自:Yue Yan
[v1] 2015年6月16日 星期二 21:12:30 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2015-06
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站