跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

天体物理学 > 天体物理仪器与方法

arXiv:1507.03850 (astro-ph)
[提交于 2015年7月14日]

标题:An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays

作者:T. Tanimori, H. Kubo, A. Takada, S. Iwaki, S. Komura, S. Kurosawa, Y. Matsuoka, K. Miuchi, S. Miyamoto, T. Mizumoto, Y. Mizumura, K. Nakamura, S. Nakamura, M. Oda, J. D. Parker, T. Sawano, S. Sonoda, T. Takemura, D. Tomono, K. Ueno
查看论文《An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
评论: 19 pages, 12 figures, Accepted to the Astrophysical Journal
主题: 天体物理仪器与方法 (astro-ph.IM); 宇宙学与河外天体物理学 (astro-ph.CO); 高能天体物理现象 (astro-ph.HE); 高能物理 - 实验 (hep-ex); 核实验 (nucl-ex)
引用方式: arXiv:1507.03850 [astro-ph.IM]
  (或者 arXiv:1507.03850v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1507.03850
期刊参考: ApJ, 810 (2015), 28
相关 DOI: https://doi.org/10.1088/0004-637X/810/1/28

提交历史

来自:Atsushi Takada
[v1] 2015年7月14日 星期二 14:00:24 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2015-07
切换浏览方式为:
astro-ph
astro-ph.CO
astro-ph.HE
hep-ex
nucl-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站