跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:1603.04846 (physics)
[提交于 2016年3月15日]

标题:Characterisation of silicon microstrip detectors for the ATLAS Phase-II Upgrade with a micro-focused X-ray beam

作者:Luise Poley, Andrew Blue, Richard Bates, Ingo Bloch, Sergio Diez, Javier Fernandez-Tejero, Celeste Fleta, Bruce Gallop, Ashley Greenall, Ingrid-Maria Gregor, Kazuhiko Hara, Yoichi Ikegami, Carlos Lacasta, Kristin Lohwasser, Dzmitry Maneuski, Sebastian Nagorski, Ian Pape, Peter W. Phillips, Dennis Sperlich, Kawal Sawhney, Urmila Soldevila, Miguel Ullan, Yoshinobu Unno, Matt Warren
查看论文《Characterisation of silicon microstrip detectors for the ATLAS Phase-II Upgrade with a micro-focused X-ray beam》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation damage at 3000 fb^-1 after ten years of operation, requiring the tracking detectors to withstand fluences to over 1*10^16 1 MeV n_eq/cm^2 . In order to cope with the consequent increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip tracker region of the ITk were characterized at the Diamond Light Source with a 3 um FWHM 15 keV micro focused X-ray beam. The devices under test were a 320 Um thick silicon stereo (Barrel) ATLAS12 strip mini sensor wire bonded to a 130 nm CMOS binary readout chip (ABC130) and a 320 Um thick full size radial (end-cap) strip sensor - utilizing bi-metal readout layers - wire bonded to 250 nm CMOS binary readout chips (ABCN-25). A resolution better than the inter strip pitch of the 74.5 um strips was achieved for both detectors. The effect of the p-stop diffusion layers between strips was investigated in detail for the wire bond pad regions. Inter strip charge collection measurements indicate that the effective width of the strip on the silicon sensors is determined by p-stop regions between the strips rather than the strip pitch.
评论: 12 pages, to be published to Journal of Instrumentation
主题: 仪器与探测器 (physics.ins-det); 高能物理 - 实验 (hep-ex)
引用方式: arXiv:1603.04846 [physics.ins-det]
  (或者 arXiv:1603.04846v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1603.04846
相关 DOI: https://doi.org/10.1088/1748-0221/11/07/P07023

提交历史

来自:Anne-Luise Poley
[v1] 2016年3月15日 星期二 08:08:53 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-03
切换浏览方式为:
physics
hep-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站