标题:Thermoluminescent characteristics of LiF:Mg,Cu,P and CaSO$_4$:Dy for low dose measurement

作者:S. Del Sol Fernández, R. García-Salcedo, J. Guzmán Mendoza, D. Sánchez-Guzmán, G. Ramírez Rodríguez, E. Gaona, T. Rivera Montalvo
查看论文《Thermoluminescent characteristics of LiF:Mg,Cu,P and CaSO$_4$:Dy for low dose measurement》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Thermoluminescence (TL) characteristics for LiF:Mg,Cu,P, and CaSO$_4$:Dy under the homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescence dosimetry is presented. The irradiation were performed utilizing a conventional X-ray equipment installed at the Hospital Ju\'arez Norte of M\'exico. Different thermoluminescence characteristics of two material were studied, such as batch homogeneity, glow curve, linearity, detection threshold, reproducibility, relative sensitivity and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and they were positioned in a generic phantom. The dose analysis, verification and comparison with the measurements obtained by the TLD-100 were performed. Results indicate that the dosimetric peak appears at 202$^o$C and 277.5$^o$C for LiF:Mg,Cu,P and CaSO$_4$:Dy, respectively. TL response as a function of X-ray dose showed a linearity behavior in the very low dose range for all materials. However, the TLD-100 is not accurate for measurements below $4mGy$. CaSO$_4$:Dy is 80\% more sensitive than TLD-100 and it show the lowest detection threshold, whereas LiF:Mg,Cu,P is 60\% more sensitive than TLD-100. All material showed very good repeatability. Fading for a period of one month at room temperature showed low fading LiF:Mg,Cu,P, medium and high for TLD-100 and CaSO$_4$:Dy. The results suggest that CaSO$_4$:Dy and LiF:Mg,Cu,P are suitable for measurements at low doses used in radiodiagnostic.
评论: 7 pages, 8 figures
主题: 仪器与探测器 (physics.ins-det); 医学物理 (physics.med-ph)
引用方式: arXiv:1604.00098 [physics.ins-det]
  (或者 arXiv:1604.00098v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1604.00098
期刊参考: Applied Radiation and Isotopes, 111, 50-55 (2016)
相关 DOI: https://doi.org/10.1016/j.apradiso.2016.02.011

提交历史

来自:Ricardo Garcia-Salcedo
[v1] 2016年4月4日 星期一 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-04
切换浏览方式为:
physics
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站