跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

天体物理学 > 天体物理仪器与方法

arXiv:1604.03273 (astro-ph)
[提交于 2016年4月12日]

标题:Spectral calibration requirements of radio interferometers for Epoch of Reionisation science with the SKA

作者:Cathryn M. Trott, Randall B. Wayth
查看论文《Spectral calibration requirements of radio interferometers for Epoch of Reionisation science with the SKA》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Spectral features introduced by instrumental chromaticity of radio interferometers have the potential to negatively impact the ability to perform Epoch of Reionisation (EoR) and Cosmic Dawn (CD) science using the redshifted neutral hydrogen emission line from the early Universe. We describe instrument calibration choices that influence the spectral characteristics of the science data, and assess their impact on EoR statistical and tomographic experiments. Principally, we consider the intrinsic spectral response of the receiving antennas, embedded within a complete frequency-dependent primary beam response, and frequency-dependent instrument sampling. We assess different options for bandpass calibration. The analysis is applied to the proposed SKA1-Low EoR/CD experiments. We provide tolerances on the smoothness of the SKA station primary beam bandpass, to meet the scientific goals of statistical and tomographic (imaging) EoR programs. Two calibration strategies are tested: (1) fitting of each fine channel independently, and (2) fitting of an nth-order polynomial for each ~1~MHz coarse channel with (n+1)th-order residuals (n=2,3,4). Strategy (1) leads to uncorrelated power in the 2D power spectrum proportional to the thermal noise power, thereby reducing the overall array sensitivity. Strategy (2) leads to correlated residuals from the fitting, and residual signal power with (n+1)th-order curvature. For the residual power to be less than the thermal noise, the fractional amplitude of a fourth-order term in the bandpass across a single coarse channel must be <2.5% (50~MHz), <0.5% (150~MHz), <0.8% (200~MHz). The tomographic experiment places stringent constraints on phase residuals in the bandpass. We find that the root-mean-square variability over all stations of the change in phase across any fine channel (4.578~kHz) should not exceed 0.2 degrees.
评论: 15 pages, accepted for publication in the Publications of the Astronomical Society of Australia
主题: 天体物理仪器与方法 (astro-ph.IM); 宇宙学与河外天体物理学 (astro-ph.CO)
引用方式: arXiv:1604.03273 [astro-ph.IM]
  (或者 arXiv:1604.03273v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1604.03273
相关 DOI: https://doi.org/10.1017/pasa.2016.18

提交历史

来自:Cathryn Trott
[v1] 2016年4月12日 星期二 07:44:10 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-04
切换浏览方式为:
astro-ph
astro-ph.CO

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站