标题:Accuracy of the geometric-mean method for determining spatial resolutions of tracking detectors in the presence of multiple Coulomb scattering

作者:Aiwu Zhang, Marcus Hohlmann
查看论文《Accuracy of the geometric-mean method for determining spatial resolutions of tracking detectors in the presence of multiple Coulomb scattering》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The geometric-mean method is often used to estimate the spatial resolution of a position-sensitive detector probed by tracks. It calculates the resolution solely from measured track data without using a detailed tracking simulation and without considering multiple Coulomb scattering effects. Two separate linear track fits are performed on the same data, one excluding and the other including the hit from the probed detector. The geometric mean of the widths of the corresponding exclusive and inclusive residual distributions for the probed detector is then taken as a measure of the intrinsic spatial resolution of the probed detector: $\sigma=\sqrt{\sigma_{ex}\cdot\sigma_{in}}$. The validity of this method is examined for a range of resolutions with a stand-alone Geant4 Monte Carlo simulation that specifically takes multiple Coulomb scattering in the tracking detector materials into account. Using simulated as well as actual tracking data from a representative beam test scenario, we find that the geometric-mean method gives systematically inaccurate spatial resolution results. Good resolutions are estimated as poor and vice versa. The more the resolutions of reference detectors and probed detector differ, the larger the systematic bias. An attempt to correct this inaccuracy by statistically subtracting multiple-scattering effects from geometric-mean results leads to resolutions that are typically too optimistic by 10-50\%. This supports an earlier critique of this method based on simulation studies that did not take multiple scattering into account.
评论: 9 pages, 7 figures, prepared for submission to JINST
主题: 数据分析、统计与概率 (physics.data-an); 高能物理 - 实验 (hep-ex); 核实验 (nucl-ex)
引用方式: arXiv:1604.06130 [physics.data-an]
  (或者 arXiv:1604.06130v1 [physics.data-an] 对于此版本)
  https://doi.org/10.48550/arXiv.1604.06130
相关 DOI: https://doi.org/10.1088/1748-0221/11/06/P06012

提交历史

来自:Aiwu Zhang
[v1] 2016年4月20日 星期三 22:05:34 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.data-an
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-04
切换浏览方式为:
physics
hep-ex
nucl-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站