跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

天体物理学 > 天体物理仪器与方法

arXiv:1605.00932 (astro-ph)
[提交于 2016年10月19日]

标题:Building the analytical response in frequency domain of AC biased bolometers Application to Planck/HFI

作者:Alexandre Sauvé, Ludovic Montier
查看论文《Building the analytical response in frequency domain of AC biased bolometers Application to Planck/HFI》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Context: Bolometers are high sensitivity detector commonly used in Infrared astronomy. The HFI instrument of the Planck satellite makes extensive use of them, but after the satellite launch two electronic related problems revealed critical. First an unexpected excess response of detectors at low optical excitation frequency for {\nu} < 1 Hz, and secondly the Analog To digital Converter (ADC) component had been insufficiently characterized on-ground. These two problems require an exquisite knowledge of detector response. However bolometers have highly nonlinear characteristics, coming from their electrical and thermal coupling making them very difficult to modelize. Goal: We present a method to build the analytical transfer function in frequency domain which describe the voltage response of an Alternative Current (AC) biased bolometer to optical excitation, based on the standard bolometer model. This model is built using the setup of the Planck/HFI instrument and offers the major improvement of being based on a physical model rather than the currently in use had-hoc model based on Direct Current (DC) bolometer theory. Method: The analytical transfer function expression will be presented in matrix form. For this purpose, we build linearized versions of the bolometer electro thermal equilibrium. And a custom description of signals in frequency is used to solve the problem with linear algebra. The model performances is validated using time domain simulations. Results: The provided expression is suitable for calibration and data process- ing. It can also be used to provide constraints for fitting optical transfer function using real data from steady state electronic response and optical response. The accurate description of electronic response can also be used to improve the ADC nonlinearity correction for quickly varying optical signals.
评论: 20 pages, 10 figures
主题: 天体物理仪器与方法 (astro-ph.IM)
引用方式: arXiv:1605.00932 [astro-ph.IM]
  (或者 arXiv:1605.00932v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1605.00932
相关 DOI: https://doi.org/10.1007/s10686-016-9514-1

提交历史

来自:Alexandre Sauvé
[v1] 2016年10月19日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-10
切换浏览方式为:
astro-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站