物理学 > 原子物理
[提交于 2016年5月12日]
标题:Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.
提交历史
来自:Jérôme Lodewyck[v1] 2016年5月12日 星期四 16:18:38 UTC