跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 核实验

arXiv:1606.00929 (nucl-ex)
[提交于 2016年11月23日]

标题:Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array

作者:K. K. H. Leung, P. Geltenbort, S. Ivanov, F. Rosenau, O. Zimmer
查看论文《Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $\tau_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $\tau_{\rm n}$ experiments with magnetically stored UCNs.
评论: To be submitted to Physical Review C
主题: 核实验 (nucl-ex); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:1606.00929 [nucl-ex]
  (或者 arXiv:1606.00929v1 [nucl-ex] 对于此版本)
  https://doi.org/10.48550/arXiv.1606.00929
相关 DOI: https://doi.org/10.1103/PhysRevC.94.045502

提交历史

来自:Kent Leung
[v1] 2016年11月23日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

nucl-ex
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-11
切换浏览方式为:
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站