凝聚态物理 > 介观与纳米尺度物理
[提交于 2016年8月24日]
标题:Microwave-free magnetometry with nitrogen-vacancy centers in diamond
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We use magnetic-field-dependent features in the photoluminescence of negatively charged nitrogen-vacancy centers to measure magnetic fields without the use of microwaves. In particular, we present a magnetometer based on the level anti-crossing in the triplet ground state at 102.4 mT with a demonstrated noise floor of 6 nT/$\sqrt{\text{Hz}}$, limited by the intensity noise of the laser and the performance of the background-field power supply. The technique presented here can be useful in applications where the sensor is placed closed to conductive materials, e.g. magnetic induction tomography or magnetic field mapping, and in remote-sensing applications since principally no electrical access is needed.
提交历史
来自:Arne Wickenbrock[v1] 2016年8月24日 星期三 00:00:00 UTC
当前浏览上下文:
cond-mat.mes-hall
切换浏览方式为: