标题:Monte Carlo simulation of a very high resolution thermal neutron detector composed of glass scintillator microfibers

作者:Song Yushou, Joseph Conner, Xiaodong Zhang, Jason P. Hayward
查看论文《Monte Carlo simulation of a very high resolution thermal neutron detector composed of glass scintillator microfibers》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption location is reconstructed from the observed charged particle products that result from neutron absorption. To suppress the cross talk of the scintillation light, each scintillating fiber is surrounded by air-filled glass capillaries with the same diameter as the fiber. This pattern is repeated to form a bulk microfiber detector. On one end, the surface of the detector is painted with a thin optical reflector to increase the light collection efficiency at the other end. Then the scintillation light emitted by any neutron interaction is transmitted to one end, magnified, and recorded by an intensified CCD camera. A simulation based on the Geant4 toolkit was developed to model this detector. All the relevant physics processes including neutron interaction, scintillation, and optical boundary behaviors are si\-mulated. This simulation was first validated through measurements of neutron response from lithium glass cylinders. With good expected light collection, an algorithm based upon the features inherent to alpha and triton particle tracks is proposed to reconstruct the neutron reaction position in the glass fiber array. Given a 1\,$\mu$m fiber diameter and 0.1\,mm detector thickness, the neutron spatial resolution is expected to reach $\sigma\sim 1\, \mu$m with a Gaussian fit in each lateral dimension. The detection efficiency was estimated to be 3.7\% for a glass fiber assembly with thickness of 0.1\,mm. When the detector thickness increases from 0.1\,mm to 1\,mm, the position resolution is not expected to vary much, while the detection efficiency is expected to increase by about a factor of ten.
主题: 仪器与探测器 (physics.ins-det); 核实验 (nucl-ex)
引用方式: arXiv:1606.03574 [physics.ins-det]
  (或者 arXiv:1606.03574v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1606.03574

提交历史

来自:Yushou Song
[v1] 2016年6月11日 星期六 09:50:52 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-06
切换浏览方式为:
physics
nucl-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站