跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:1608.07069 (physics)
[提交于 2016年8月25日]

标题:Microelectrode arrays of diamond-insulated graphitic channels for real time detection of exocytotic events from cultured chromaffin cells and slices of adrenal glands

作者:F. Picollo, A. Battiato, E. Bernardi, A. Marcantoni, A. Pasquarelli, E. Carbone, P. Olivero, V. Carabelli
查看论文《Microelectrode arrays of diamond-insulated graphitic channels for real time detection of exocytotic events from cultured chromaffin cells and slices of adrenal glands》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A microstructured graphitic 4x4 multielectrode array was embedded in a single crystal diamond substrate (4x4 {uG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20x3.5 um^2) separated by 200 um gaps. Taking advantage of the array geometry we addressed the following specific issues: i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, ii) resolve the waveform of different subsets of exocytotic events, iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 Hz and 0.3 Hz respectively for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated to "full fusion" events, "kiss and-run" and "kiss-and-stay" exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.
主题: 仪器与探测器 (physics.ins-det); 生物物理 (physics.bio-ph)
引用方式: arXiv:1608.07069 [physics.ins-det]
  (或者 arXiv:1608.07069v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1608.07069
期刊参考: Analytical Chemistry 88, 7493-7499 (2016)
相关 DOI: https://doi.org/10.1021/acs.analchem.5b04449

提交历史

来自:Paolo Olivero
[v1] 2016年8月25日 星期四 09:54:38 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-08
切换浏览方式为:
physics
physics.bio-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站