标题:First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation

作者:E. Solfaroli Camillocci, M. Schiariti, V. Bocci, A. Carollo, G. Chiodi, M. Colandrea, F. Collamati, M. Cremonesi, R. Donnarumma, M. E. Ferrari, P. Ferroli, F. Ghielmetti, C. M. Grana, M. Marafini, S. Morganti, C. Mancini Terracciano, M. Patanè, G. Pedroli, B. Pollo, L. Recchia, A. Russomando, M. Toppi, G. Traini, R. Faccini
查看论文《First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex-vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection. Methods: A patient affected by meningioma was administered 300 MBq of 90Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a beta- probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation. Results: we obtained a large signal on the bulk tumor (105 cps) and a significant signal on residuals of $\sim$0.2 ml (28 cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (~1 cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity. Conclusions: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.
评论: 17 pages, 4 Figs, Accepted by Physica Medica
主题: 仪器与探测器 (physics.ins-det); 医学物理 (physics.med-ph)
引用方式: arXiv:1608.08364 [physics.ins-det]
  (或者 arXiv:1608.08364v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1608.08364
期刊参考: Phys. Med. 32(9) 1139 (2016)
相关 DOI: https://doi.org/10.1016/j.ejmp.2016.08.018

提交历史

来自:Riccardo Faccini
[v1] 2016年8月30日 星期二 08:35:11 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-08
切换浏览方式为:
physics
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站