[提交于 2016年9月13日]

标题:Bayesian electron density inference from JET lithium beam emission spectra using Gaussian processes

作者:Sehyun Kwak, J. Svensson, M. Brix, Y. -c. Ghim
查看论文《Bayesian electron density inference from JET lithium beam emission spectra using Gaussian processes》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A Bayesian model to infer edge electron density profiles is developed for the JET lithium beam emission spectroscopy system, measuring Li I line radiation using 26 channels with ~1 cm spatial resolution and 10~20 ms temporal resolution. The density profile is modelled using a Gaussian process prior, and the uncertainty of the density profile is calculated by a Markov Chain Monte Carlo (MCMC) scheme. From the spectra measured by the transmission grating spectrometer, the Li line intensities are extracted, and modelled as a function of the plasma density by a multi-state model which describes the relevant processes between neutral lithium beam atoms and plasma particles. The spectral model fully takes into account interference filter and instrument effects, that are separately estimated, again using Gaussian processes. The line intensities are inferred based on a spectral model consistent with the measured spectra within their uncertainties, which includes photon statistics and electronic noise. Our newly developed method to infer JET edge electron density profiles has the following advantages in comparison to the conventional method: i) providing full posterior distributions of edge density profiles, including their associated uncertainties, ii) the available radial range for density profiles is increased to the full observation range (~26 cm), iii) an assumption of monotonic electron density profile is not necessary, iv) the absolute calibration factor of the diagnostic system is automatically estimated overcoming the limitation of the conventional technique and allowing us to infer the electron density profiles for all pulses without preprocessing the data or an additional boundary condition, and v) since the full spectrum is modelled, the procedure of modulating the beam to measure the background signal is only necessary for the case of overlapping of the Li line with impurity lines.
评论: 18 pages and 8 figures
主题: 等离子体物理 (physics.plasm-ph)
引用方式: arXiv:1609.03787 [physics.plasm-ph]
  (或者 arXiv:1609.03787v1 [physics.plasm-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1609.03787
相关 DOI: https://doi.org/10.1088/1741-4326/aa5072

提交历史

来自:Sehyun Kwak
[v1] 2016年9月13日 星期二 12:01:07 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.plasm-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-09
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站