跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1609.06712 (physics)
[提交于 2016年9月21日]

标题:Design, characterization and visual performance of a new multizone contact lens

作者:Manuel Rodriguez-Vallejo, Clara Llorens-Quintana, Juan A. Monsoriu, Walter D. Furlan
查看论文《Design, characterization and visual performance of a new multizone contact lens》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objectives: To analyze the whole process involved in the production of a new bifocal Multizone Contact Lens (MCL) for presbyopia. Methods: The optical quality of a new MCL was evaluated by ray tracing software in a model eye with pupil different diameters with the lens centered and decentered. A stock of low addition (+1.5 D) MCL for presbyopia was ordered for manufacturing. Power profiles were measured with a contact lens power mapper, processed with a custom software and compared with the theoretical design. Nine lenses from the stock were fitted to presbyopic subjects and the visual performance was evaluated with new APPs for iPad Retina. Results: Numerical simulations showed that the trough the focus curve provided by MCL has an extended depth of focus. The optical quality was not dependent on pupil size and only decreased for lens decentered with a pupil diameter of 4.5 mm. The manufactured MCL showed a smoothed power profile with a less-defined zones. The bias between experimental and theoretical zone sizes was uniform along the optical zone unless for the most central area. Eyes fitted with the manufactured MCL showed an improvement in near Visual Acuity (VA) and near stereopsis. Althouh Contrast Sensitivity (CS) at distance decreased, the defocus curve for contrast showed an extended depth of focus correlated to the ray tracing results. Conclusions: The understanding of vision with MCL requires a process that involves design and characterization for detecting any defect that may have impact in the final visual performance. Keywords: Multifocal contact lenses, design, characterization, visual performance
评论: 12 pages, 4 figures, 2 Tables
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1609.06712 [physics.med-ph]
  (或者 arXiv:1609.06712v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1609.06712

提交历史

来自:Manuel Rodriguez-Vallejo
[v1] 2016年9月21日 星期三 17:55:17 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-09
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站